ARCHIVE
january 2023
december 2022
november 2022
october 2022
september 2022
august 2022
july 2022
june 2022
may 2022
april 2022
march 2022
february 2022
december 2021
november 2021
october 2021
september 2021
august 2021
july 2021
april 2021
march 2021
february 2021
january 2021
december 2020
november 2020
october 2020
september 2020
august 2020
july 2020
june 2020
may 2020
april 2020
march 2020
february 2020
january 2020
december 2019
october 2019
august 2019
may 2019
march 2019
february 2019
january 2019
december 2018
november 2018
october 2018
september 2018
august 2018
july 2018
april 2018
march 2018
february 2018
january 2018
december 2017
november 2017
october 2017
september 2017
august 2017
july 2017
june 2017
may 2017
april 2017
march 2017
february 2017
january 2017
december 2016
november 2016
october 2016
september 2016
august 2016
july 2016
june 2016
may 2016
april 2016
march 2016
february 2016
january 2016
december 2015
november 2015
october 2015
september 2015
august 2015
july 2015
june 2015
may 2015
april 2015
march 2015
february 2015
january 2015
december 2014
november 2014
october 2014
september 2014
august 2014
july 2014
june 2014
may 2014
april 2014
march 2014
february 2014
january 2014
december 2013
november 2013
october 2013
september 2013
august 2013
july 2013
june 2013
may 2013
april 2013
march 2013
february 2013
january 2013
april 2011

Installing the safety valve

Some criteria for installing the safety valve in the system

Let's talk about the safety valve and its use for protecting heating systems from overpressure, which can damage the components and above all create a hazard to persons. 
The safety valve only intervenes when the pressure in the system generates a force greater than the one created from the setting spring, this leads to a discharge of the flowing fluid in order to bring the system back to a safe condition. 
The field of application is that of systems with power generators up to 35 KW and may only be used if made, as is the case of the GNALI BOCIA safety valve, in accordance with the "Collection R" requirements for safety rules for pressure apparatuses. 
They are used to protect storage tanks. The mounting can be in a vertical or horizontal position, but never in an inverted position in order to avoid the accumulation of impurities that could damage the sealing disc over time. There must be no shut-off valves between the safety valve and the device to be protected.  
Once the device becomes operational, it does not close until the pressure has dropped to a value at least 20% lower than that of calibration. 
If a drain pipe is required, it must be specified that this must not in any way prevent the correct operation of the valve and must have a diameter at least equal to that of the outlet connection.
 

13/11/2014


See also
13/08/2019 Operation and assembly of the safety valves

13/02/2015 Safety valves are necessary for your own protection Protect your system against damages by using a safety valve to be applied to the output of your generator.

13/09/2014 System safety with the boiler safety valve Prevent problems and damages to your system by using a boiler safety valve